Getting Data In

Can you help me with the following error on my universal forwarder: "Monotonic time source didn't increase; is it stuck?"

vulnfree
Explorer

I am receiving the following errors from my universal forwarder: "Monotonic time source didn't increase; is it stuck?"

How do I resolve this?

0 Karma

stefanghita
Engager

I had the same question and I opened a Splunk case. This is the response:

"This is an error we have come across with some of our Windows customers, and seems more common of virtualized instances. The splunk process will periodically check the time of the OS system and will show this error if there is a difference (~15 ms) as an indication of the time progress internally. This is really an internal ERROR that should not be reported.

Reference: GetTickCount64 function https://docs.microsoft.com/en-gb/windows/win32/api/sysinfoapi/nf-sysinfoapi-gettickcount64

This issue is currently fixed in version 8.0.0, and if you would like to stop this error from occurring, you will need to look into upgrading to 8.0, otherwise, you can ignore this error message.​"

0 Karma

chrisyounger
SplunkTrust
SplunkTrust

Not sure sorry. You might need to raise a ticket with Splunk.

Are your UFs running on an VMware or virtualisation stack and maybe they aren't getting enough CPU time? Alternatively, did the system clock change or did a timezone change occur?

Good luck

0 Karma
Get Updates on the Splunk Community!

Index This | I’m short for "configuration file.” What am I?

May 2024 Edition Hayyy Splunk Education Enthusiasts and the Eternally Curious!  We’re back with a Special ...

New Articles from Academic Learning Partners, Help Expand Lantern’s Use Case Library, ...

Splunk Lantern is a Splunk customer success center that provides advice from Splunk experts on valuable data ...

Your Guide to SPL2 at .conf24!

So, you’re headed to .conf24? You’re in for a good time. Las Vegas weather is just *chef’s kiss* beautiful in ...