Deployment Architecture

maxWarmDBCount limit exceeded

chrisduimstra
Path Finder

I am using different storage drives for hot/warm and cold storage. The Fire Brigade app was reporting a total of 524 buckets for index A with a limit of 300. I verified on the storage drive that there are 524 buckets. The indexes.conf file has the following settings which should trigger the rotation policy, maxWarmDBCount = 300 and rotatePeriodInSecs = 60. Why are the buckets not rolling from warm to cold?

0 Karma

lycollicott
Motivator

Is the cold location correct? Accessible? Have the correct permissions and ownership?

chrisduimstra
Path Finder

I ran a search for bucketmover and discovered splunk did not have permissions to remove inflight-db... folders in the cold storage that had my user account permissions only and not the permissions for the account which splunk was running under. I enabled inheritance on the storage drive and splunk was able to move the buckets afterwards.

0 Karma

lycollicott
Motivator

Cool. We have had the exact same issue, so I created an alert for this :

index=_internal sourcetype=splunkd log_level=ERROR component=BucketMover "inflight-" "access is denied earliest=-1m latest=now"

We run it every minute instead of realtime and then we act on it.

0 Karma
Get Updates on the Splunk Community!

Modern way of developing distributed application using OTel

Recently, I had the opportunity to work on a complex microservice using Spring boot and Quarkus to develop a ...

Enterprise Security Content Update (ESCU) | New Releases

Last month, the Splunk Threat Research Team had 3 releases of new security content via the Enterprise Security ...

Archived Metrics Now Available for APAC and EMEA realms

We’re excited to announce the launch of Archived Metrics in Splunk Infrastructure Monitoring for our customers ...